Casella-cel CEL-633 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Messgeräte Casella-cel CEL-633 herunter. Casella CEL CEL-633 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 2
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Figure 9. Memory screens
2
3
4
1
1
2
3
4
5
6
7
1. Windshield (covering the removable microphone)
2. Fixed amplifier
3. On/Off key
4. Display
Introduction
This Quick Start guide helps you to familiarise yourself with the CEL-63x instrument
quickly, so that you can begin to use it without delay.
The guide assumes this is the first time you have used the instrument. It therefore
includes instructions to install the batteries, switch ON and set up the instrument to be
ready for use, calibrate it, take measurements, and store it safely.
We want you to get the best possible performance from the CEL-63x instrument, and
we recommend you refer to the Operator’s Manual for detailed information.
Field Guide
CEL-63x Series Sound Level Meters
CASELLA MEASUREMENT
Regent House, Wolseley Road, Kempston, Bedford, MK42 7JY, U.K.
Phone: +44 (0) 1234 844 100
Fax: +44 (0) 1234 841 490
E-mail for technical support: [email protected]
For online Technical Support: http://supportdesk.casellacel.com
Figure 1. The CEL-63x series
5. Soft keys and
6. Navigation keys
7. Run/Stop key
A B
C
D
A
B
Taking Measurements (Refer to Figure 10)
The measurement options and screen details will vary, depending on the instrument
type you are using.
The instrument must be in the Measurement Stop mode (with red bars at the top and
bottom of the screen) before you can start a measurement.
Press the Run/Stop key ( ) to start making measurements. The screen shows green
bars at the top and bottom.
D
Certain instrument types provide two additional Octave (or 1/3 Octave) screens (refer
to Figure 12). Use the View key ( ) to toggle the screens. Use the left/right navigation
keys ( ) to move across the frequency bands in the Graph view. Use the up/down
navigation keys to toggle between showing L and L functions
max eq
Each bar in the graph represents an octave band measured in Hz or kHz. To view a
table of the octave values, press the View key ( ).
In 1/3 Octave mode, use the up/down navigation keys to change the displayed
frequencies on the table.
Some instruments in the CEL-63x range can display all the screens shown in
Figure 11 and Figure 12.
The Marker screen allows you to tag noise data, for example noise from a road
vehicle, with a specific identity using one of four markers.
When the measurement run has finished, press the Run/Stop key ( ). A screen is
displayed asking you to confirm the action - press Yes to end the run.
B
C
B
D
Storage
More information
Switch the CEL-63x instrument off when you are not using it to record measurements,
and remove the batteries if the instrument will not be used for extended periods of
time.
Always protect the instrument from physical damage and from water.
To protect the microphone, you should always keep the windshield fitted.
For more information about any of the topics summarised in this Quick Start guide,
refer to the User Manual.
Instrument types
Table 1 below lists the instrument types and shows the capabilities of each
instrument in the range. Please remember that the features that are available to you
and the screens that you can see depend on the type of instrument you are using.
Table 1. CEL-63x instrument types, applications and capabilities
Document number FG40-03 © 2010 Casella Measurement
Figure 10. Example Stop and Run screens
Run Screens
The Play symbol is displayed at the top left-hand corner of the screen, and the
Pause symbol is displayed at the bottom left-hand corner of the screen. The left-
hand soft key ( ) is the Pause/Run control and toggles between these two modes
when operated.
The screen displays PAUSED! when measurements are paused. The incremental
run number and its duration are displayed at the top right-hand corner of the screen. If
the Run Duration Timer is set, an icon that shows a stopwatch is displayed next to the
countdown timer. To enable or disabled the Run Duration Timer, use the Settings
screens (refer to Figure 6). If the Run Duration Timer is not set, the digital timer clock
counts up until you stop the measurement run manually (by pressing the Run/Stop
key ).
For instruments that include this option, the broadband values can be viewed as a
bargraph or as a graphical time history on the Graph screen. Press the View key ( )
to toggle between the Graph and the Main screens.
4
;
A
D
B
Figure 11. Graph and Main screens
Figure 12. graph and list views1/3 Octave
Store cumulative data
Data markers
Logging of Time History
Automatic On/Off timers
Run duration timers
Application
Model number
Environmental
(with logging)
Occupational
Environmental
Occupational
(with logging)
CEL-633
CEL-630
CEL-631
CEL-632
Statistical parameters (Ln%)
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - Field Guide

Figure 9. Memory screens234112345671. Windshield (covering the removable microphone)2. Fixed amplifier3. On/Off key4. DisplayIntroductionThis Quick St

Seite 2 - Delete Memory Results

Fit the batteriesSwitch the instrument ONSettings screenThe CEL-63x instrument requires three AA batteries.Remove the battery compartment cover

Verwandte Modelle: CEL-632 | CEL-631 | CEL-630 |

Kommentare zu diesen Handbüchern

Keine Kommentare