Casella-cel AFC123 Bedienungsanleitung Seite 20

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 24
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 19
Casella USA
17 Old Nashua Road #15
Amherst, NH 03031
Web www.casellausa.com
TF (800) 366-2966
AFC123 Personal Sampler. Page 20
Handbook No. HB3182-02 Issue2/JULY 1994
Accessories.
HK2 Eccentric to motor shaft
(Hexagon wrench)
HK304 Flow adjustment
Service Hints:-
Symptom:- Pump does not run (green LED illuminated).
Possible cause:-
Service Hint
Battery fully discharged. Replace with fully
charged battery.
Wiring loom disconnected at some point. Locate and resolder.
Fault on joint. Replace circuit
board.
Symptom:-Pump does not run (green LED illuminated).
Possible cause:-
Service Hint.
Eccentric bearing seizure. Replace bearing.
Motor shaft seizure Replace motor.
Symptom:-Motor runs but pump inoperative.